Clinical calculators · Electrolytes and osmolality
Calculated serum osmolality and osmolar gap
The osmolality the measured solutes account for, and the gap left over.
Also called osmolar gap, osmolal gap
Values
BUN, not urea. To convert urea in mmol/L to BUN in mg/dL, multiply by 2.8.
Optional. Given it, the osmolar gap is shown.
Result
Enter the values on the left. The answer appears here as you type, and nothing is sent anywhere.
Check the result against an independent reference before acting on it. A calculator agreeing with itself is not a check.
The formula
- Calculated osmolality = 2 × Na + glucose (mg/dL) ÷ 18 + BUN (mg/dL) ÷ 2.8
- Osmolar gap = measured osmolality − calculated osmolality
Where it comes from
Smithline N & Gardner KD, Gaps — anionic and osmolal, JAMA 1976;236(14):1594-7.
Several variants circulate, some adding ethanol ÷ 3.7 and some using 1.86 × Na. This is the commonest three-term form; the difference matters when the gap is borderline.
What it does not account for
The arithmetic is the easy part. These are the reasons a correct number can still be the wrong number to act on.
- A raised gap suggests an unmeasured osmole but does not say which. Methanol, ethylene glycol, isopropanol, ethanol, mannitol, glycine and propylene glycol all raise it, and so does laboratory error.
- Ethanol is the commonest cause by far. Where ethanol is known, many clinicians add ethanol ÷ 3.7 to the calculated value; this tool does not, so an intoxicated patient will show a gap.
- A NORMAL gap does not exclude toxic alcohol poisoning late in its course, once the parent alcohol has been metabolised to acids. By then the anion gap is the finding.
- Measured osmolality must be by freezing-point depression. A vapour-pressure osmometer does not detect volatile alcohols at all.
- The reference range for the gap is method-dependent and narrow; a published cut-off of 10 has poor specificity.
No result is saved
There is no “save to chart” here, deliberately. A derived value stored beside its inputs can disagree with them — and when it does, nothing about the stored number says which is wrong or when its inputs were measured. SendClinic calculates values like these from the measurements in the chart each time they are shown, rather than keeping a copy that can go stale.