Clinical calculators · Kidney function
Creatinine clearance (Cockcroft–Gault)
Estimated creatinine clearance in mL/min — the figure most drug labels were written against.
Also called CrCl, Cockcroft-Gault
Values
Both equations were derived in adults and are not valid in children.
Both equations carry a sex coefficient, so this changes the result.
Which weight to use — actual, ideal or adjusted — is your decision. See the limits below.
1.0 mg/dL = 88.4 µmol/L. Getting this wrong changes the answer about elevenfold, so it is asked rather than assumed.
Result
Enter the values on the left. The answer appears here as you type, and nothing is sent anywhere.
Check the result against an independent reference before acting on it. A calculator agreeing with itself is not a check.
The formula
- CrCl (mL/min) = ((140 − age) × weight (kg)) ÷ (72 × serum creatinine (mg/dL))
- × 0.85 if female
Where it comes from
Cockcroft DW & Gault MH, Prediction of creatinine clearance from serum creatinine, Nephron 1976;16(1):31-41.
Derived in 249 men; the 0.85 female factor was an assumption in the original paper rather than a fitted coefficient.
What it does not account for
The arithmetic is the easy part. These are the reasons a correct number can still be the wrong number to act on.
- This is NOT eGFR and the two are not interchangeable. Use this for renal drug dosing, where the label was written against creatinine clearance, and CKD-EPI for staging kidney disease.
- It assumes creatinine is at steady state. In acute kidney injury the creatinine lags the injury by a day or more, so this overestimates function in exactly the situation where it matters most.
- It is unreliable at the extremes of muscle mass — the very muscular, the cachectic, amputees — because creatinine production is a function of muscle, not of kidney.
- Which weight to use is a clinical decision this tool does not make. Actual, ideal and adjusted body weight all appear in the literature and give different answers.
- Derived in adults. It is not valid in children.
No result is saved
There is no “save to chart” here, deliberately. A derived value stored beside its inputs can disagree with them — and when it does, nothing about the stored number says which is wrong or when its inputs were measured. SendClinic calculates values like these from the measurements in the chart each time they are shown, rather than keeping a copy that can go stale.