Anion gap

The gap, and the albumin-corrected gap, which are often different.

Also called AG, albumin-corrected anion gap

Values

Optional

Optional. Given it, the albumin-corrected gap is shown as well — which is the one that matters in critical illness.

Result

Enter the values on the left. The answer appears here as you type, and nothing is sent anywhere.

Check the result against an independent reference before acting on it. A calculator agreeing with itself is not a check.

The formula

  • AG = Na − (Cl + HCO₃)
  • Albumin-corrected AG = AG + 2.5 × (4.0 − albumin (g/dL))

Where it comes from

Emmett M & Narins RG, Clinical use of the anion gap, Medicine 1977;56(1):38-54. Figge J et al., Anion gap and hypoalbuminemia, Crit Care Med 1998;26(11):1807-10, for the albumin correction.

Potassium is NOT included. Both forms are in use; the three-term version is the commoner one and is what the reference ranges in most laboratories assume.

What it does not account for

The arithmetic is the easy part. These are the reasons a correct number can still be the wrong number to act on.

  • The reference range depends on the laboratory's method, and has drifted down over decades as chloride assays changed. A 'normal' gap of 8–16 is from older methodology; many modern labs run lower.
  • Hypoalbuminaemia masks a raised gap — roughly 2.5 mEq/L of apparent gap per 1 g/dL of albumin below 4. In a critically ill patient with an albumin of 2, an uncorrected gap can look normal while a significant acidosis is present.
  • A normal gap does not exclude a metabolic acidosis; it points to the hyperchloraemic kind.
  • This does not include potassium. If your laboratory's reference range does, the numbers are not comparable.

No result is saved

There is no “save to chart” here, deliberately. A derived value stored beside its inputs can disagree with them — and when it does, nothing about the stored number says which is wrong or when its inputs were measured. SendClinic calculates values like these from the measurements in the chart each time they are shown, rather than keeping a copy that can go stale.